pydicomを利用して、DICOM Tag を表示させます。
Pydicom
Pydicom |
Pydicom Dicom (Digital Imaging in Medicine) is the bread and butter of medical image datasets, storage and transfer. ...
インストール方法
pip install pydicom
フォルダ構成
以下のようなフォルダ構成とします
フォルダ
L pydicomTest.py ※python名は任意
L CR_JPG_IR87a.dcom ※見たいDICOMファイル
![](https://lemonex.shop/wp-content/uploads/2021/05/image-12.png)
プログラム
import pydicom
def main():
ds = pydicom.read_file('CR_JPG_IR87a.dcm')
print(ds)
if __name__ == "__main__":
main()
![](https://lemonex.shop/wp-content/uploads/2021/05/image-11.png)
実行結果
python .\pydicomTest.py
![](https://lemonex.shop/wp-content/uploads/2021/05/image-10-1024x471.png)
PS E:\DICOM> python .\pydicomTest.py
Dataset.file_meta -------------------------------
(0002, 0000) File Meta Information Group Length UL: 174
(0002, 0001) File Meta Information Version OB: b'\x00\x01'
(0002, 0002) Media Storage SOP Class UID UI: Computed Radiography Image Storage
(0002, 0003) Media Storage SOP Instance UID UI: 1.2.392.200036.8120.100.20081117.116584
(0002, 0010) Transfer Syntax UID UI: JPEG Lossless, Non-Hierarchical, First-ue 1])
(0002, 0012) Implementation Class UID UI: 1.2.826.0.1.3680043.2.1545.1
-------------------------------------------------
(0008, 0005) Specific Character Set CS: ['', 'ISO 2022 IR 87']
(0008, 0008) Image Type CS: ['ORIGINAL', 'PRIMARY']
(0008, 0016) SOP Class UID UI: Computed Radiography Image Storage
(0008, 0018) SOP Instance UID UI: 1.2.392.200036.8120.100.20081117.116584
(0008, 0020) Study Date DA: '20081117'
(0008, 0021) Series Date DA: '20081117'
(0008, 0022) Acquisition Date DA: '20081117'
(0008, 0023) Content Date DA: '20081117'
(0008, 0030) Study Time TM: '165844.000'
(0008, 0031) Series Time TM: '165906.000'
(0008, 0032) Acquisition Time TM: '165906.000'
(0008, 0033) Content Time TM: '165906.000'
(0008, 0050) Accession Number SH: 'CR12345678'
(0008, 0060) Modality CS: 'CR'
(0008, 0070) Manufacturer LO: 'JIRA'
(0008, 0080) Institution Name LO: 'JIRA HOSPITAL'
(0008, 0090) Referring Physician's Name PN: 'SHIROGANE^HIDEO=白金^英雄=しろがね^ひで
(0008, 1010) Station Name SH: 'ST001'
(0008, 1030) Study Description LO: ''
(0008, 103e) Series Description LO: ''
(0008, 1070) Operators' Name PN: 'HOSYASEN^TARO=放射線^太郎=ほうしゃせん
(0008, 1090) Manufacturer's Model Name LO: 'CR0001'
(0010, 0010) Patient's Name PN: 'AKIHABARA^TARO==)MU86^太郎=あきはばら^
(0010, 0020) Patient ID LO: '2008123456'
(0010, 0030) Patient's Birth Date DA: '19790201'
(0010, 0040) Patient's Sex CS: 'M'
(0010, 1020) Patient's Size DS: None
(0010, 1030) Patient's Weight DS: None
(0018, 0015) Body Part Examined CS: 'CHEST'
(0018, 0060) KVP DS: "125.0"
(0018, 1000) Device Serial Number LO: 'A0123456'
(0018, 1020) Software Versions LO: 'JIRAVer1.0'
(0018, 1110) Distance Source to Detector DS: "1800.0"
(0018, 1150) Exposure Time IS: "500"
(0018, 1151) X-Ray Tube Current IS: "100"
(0018, 1152) Exposure IS: "50"
(0018, 1155) Radiation Setting CS: 'GR'
(0018, 5100) Patient Position CS: ''
(0018, 5101) View Position CS: 'AP'
(0020, 000d) Study Instance UID UI: 1.2.392.200036.8120.100.20081117.116584
(0020, 000e) Series Instance UID UI: 1.2.392.200036.8120.100.20081117.116584
(0020, 0010) Study ID SH: '58'
(0020, 0011) Series Number IS: "1"
(0020, 0012) Acquisition Number IS: "1"
(0020, 0013) Instance Number IS: "1"
(0020, 0020) Patient Orientation CS: ''
(0020, 0060) Laterality CS: ''
(0028, 0002) Samples per Pixel US: 1
(0028, 0004) Photometric Interpretation CS: 'MONOCHROME2'
(0028, 0010) Rows US: 3000
(0028, 0011) Columns US: 3000
(0028, 0030) Pixel Spacing DS: [0.143, 0.143]
(0028, 0100) Bits Allocated US: 16
(0028, 0101) Bits Stored US: 12
(0028, 0102) High Bit US: 11
(0028, 0103) Pixel Representation US: 0
(0028, 1040) Pixel Intensity Relationship CS: 'LIN'
(0028, 1050) Window Center DS: "2048.0"
(0028, 1051) Window Width DS: "4095.0"
(7fe0, 0010) Pixel Data OB: Array of 7948260 elements
DICOM入門 | ハ-マン・オ-ステルウィック, 日本画像医療システム工業会 |本 | 通販 | Amazon
Amazonでハ-マン・オ-ステルウィック, 日本画像医療システム工業会のDICOM入門。アマゾンならポイント還元本が多数。ハ-マン・オ-ステルウィック, 日本画像医療システム工業会作品ほか、お急ぎ便対象商品は当日お届けも可能。またDICOM入門もアマゾン配送商品なら通常配送無料。
コメント